Back to: Software for Data Acquisition and Analysis

SutterPatch®

PrintShare
Data Acquisition, Management and Analysis Software (Sutter Instrument)
Sutter Instrument  SutterPatch®  Data Acquisition, Management and Analysis Software
Description

 

SutterPatch® software is a full-featured electrophysiology data acquisition, management and analysis application for Windows or Mac OS computers. SutterPatch comes bundled with all Sutter Instrument Patch Clamp Amplifier Systems. The software controls data acquisition, provides real-time measurements to aid decision making during the experiment, keeps track of all amplifier parameters, records the experimental progress and stores a set of up to 600 metadata parameters. Built within the latest version of Igor Pro by WaveMetrics, Inc., SutterPatch provides immediate access to Igor’s powerful scientific and engineering analysis tools.

Version 2 of SutterPatch software adds support for the new dPatch® Digital Patch Amplifier System as well as a multitude of new features and user interface improvements that also apply to the IPA Family of Amplifier Systems. The Membrane Test and Free Run have been upgraded. New triple slider and 2D-matrix controls facilitate compensation adjustments in the Amplifier Control Panel.

Particular emphasis was put into intuitive navigation through large data sets. Controls that are familiar from electrophysiology software or applications in other fields, as well as entirely new approaches make finding a particular section of an experiment very easy.

The structured architecture of the data files was designed to retain the context of every sample within an experiment. With little effort at the beginning of an experiment, a plethora of metadata parameters are recorded – automatically where possible, configured by the user where desired. Each parameter can be reviewed before a Paradigm or Routine is executed.

SutterPatch software comes with a collection of sample Paradigms and Routines that facilitate the configuring of commonly executed experimental scenarios.

SutterPatch provides real-time analysis capability that automatically creates graphs like I-V curves or a time course plot while the experiment is in progress. Up to 8 analysis graphs can be shown, each derived from 16 possible measurements from the input signals. Analyses include mean, slope, rise time, frequency of threshold crossing, etc. This facilitates making decisions about the further course of an experiment.

In addition to real-time analysis, SutterPatch supports further processing after the experiment for the most sophisticated analysis procedures. SutterPatch adds application-specific capabilities on top of the expansive analysis feature set that is native to Igor Pro. Equations and Variables facilitate the use of more complex algorithms in both Routines and Paradigms.

 

Features

 

 

 

System Requirements

for the IPA family systems

Minimum Configuration:
Operating System: Windows 10 (64-bit) or later, or MacOS: 10.11, El Capitan or later
Processor: Dual-core i5
Memory: 3 GB
Hard Disk: 500 GB or greater
Display Resolution: 1024 × 768 (XGA)
1 available USB 2.0 High Speed port

Recommended Configuration:
Windows 10 (64-bit) or later, or MacOS: 10.11, El Capitan or later
Processor: Dual-core i5
Memory: 8 GB
Solid-state drive (SSD): 500 GB or greater
Display Resolution: 1920 × 1080 (FULL HD)
1 available USB 2.0 High Speed port

 

for dPatch systems

Minimum Configuration:
Windows 10 (64-bit), or MacOS: 10.11, El Capitan or later
Processor: Dual-core i5
Memory: 6 GB
Solid-state drive (SSD): 500 GB or greater
Display Resolution: 1024 x 768 (XGA)
1 available USB 3.0 SuperSpeed port (on the main board, not a PCIx card or similar)

Recommended Configuration:
Windows 10 (64-bit), or MacOS: 10.11, El Capitan or later
Processor: Dual-core i5
Memory: 16 GB
Solid-state drive (SSD): 500 GB or greater
Display resolution 1920 x 1080 (Full HD)
1 available USB 3.0 SuperSpeed port (on the main board, not a PCIx card or similar)

SUTTERPATCH® Data Acquisition Management System and Analysis Software: Included with all Sutter Instrument Amplifier Systems

 

Notes:

USB 3.0 ports are compatible with USB 2.0 High Speed specifications.
Slower USB 2.0 ‘full-speed’ ports, which are sometimes found on older Windows PCs or USB add-in cards, are not supported.

To check for High Speed USB 2.0 or USB 3.0 on a PC computer running Windows, look in the Control Panel > Device Manager > Universal Serial Bus controllers section for “Enhanced” host controllers. As this does not provide any mapping information to the computer’s physical ports, and there can be a mix of USB port versions, you should check individual USB ports for USB 2.0/3.0 High Speed operational performance. As a visual indicator, USB 3.0 ports are often color coded blue.

USB hubs are not supported. USB add-in cards, even if they formally meet High Speed or Super Speed specifications, are not recommended. They are often architecturally configured as USB hubs and may lead to intermittent transfer errors that are hard to troubleshoot.

Operating systems installed within virtualization software platforms such as VMware and Parallels are not supported.

Information about environmental parameters and a more detailed specification of sample properties can be recorded and stored with the raw data. A total of over 600 metadata attributes are supported. Examples include: animal species, genotype, date/time when a cell sample was prepared, recording solutions, pipette resistance, hardware properties, and detailed information about stimuli applied.

 

 
 

Also See:

Sutter Instrument Flagship
dPatch®

Low-Noise Ultra-fast
Digital Patch Clamp Amplifier System

Dynamic Clamping
Dynamic Clamp

for the
dPATCH® Patch Clamp Amplifier

Sutter's Patch Clamp Working Horse
IPA® / DOUBLE IPA®

Integrated Patch Clamp
Amplifier System

Sutter Instrument Flagship
Dendrite ™

Data Acquisition,
Management and Analysis System

Microscope
BOB

Well suited microscope
for the electrophysiological setup

Comparison Amplifier Systems
Comparison of IPA with dPatch


(PDF file)

Experiments of Interest involving the IPA family of Integrated Patch Clamp Amplifier Systems
IPA Publications


(PDF file, external link)