Microwire Arrays (MWA)
Designed for chronic experiments, the MicroProbes Microwire Arrays (MWA) provide the optimum in flexibility and affordable alternative for the neuroscience community.
Features
- Up to 32 penetrating wires per array for short- and long-term recordings.
- Custom wire length (5-23 mm), including different length for each row.
- Custom spacing between wires is in the range of 250 - 1000 µm.
- Custom wire diameter options available (25/50 µm).
- Custom impedance for individual wires between 200-800 kΩ.
- Stainless steel and Platinum/Iridium fine wires with teflon or polyimide insulation material.
- Custom reference and ground electrodes according to the researcher’s requirements.
- Optionally integrated fiber optic and/or drug delivery cannula.
MWA Characteristics
Microwire Array Characteristics
Impedance Values
Impedance values per Metal type and Wire size
Metal type | Wire thickness | Impedance |
Pt/Ir | 25 µm | 0.4 to 0.8 MΩ |
Pt/Ir | 50 µm | 0.2 to 0.4 MΩ |
Stainless Steel | 25 µm | 0.6 to 0.9 MΩ |
Stainless Steel | 50 µm | 0.4 to 0.6 MΩ |
Publications:
Axial levodopa-induced dyskinesias and neuronal activity in the dorsal striatum
Levodopa-induced dyskinesias are abnormal involuntary movements that limit the effectiveness of...
Corticostriatal Field Potentials Are Modulated at Delta and Theta Frequencies during Interval-Timing Task in Rodents
Organizing movements in time is a critical and highly conserved feature of mammalian behavior...
D1-dependent 4 Hz oscillations and ramping activity in rodent medial frontal cortex during interval timing
Organizing behavior in time is afundamental process that is highly conserved across species.Here...
Electrophysiological evidence of alterations to the nucleus accumbens and dorsolateral striatum during chronic cocaine self-administration
As drug use becomes chronic, aberrant striatal processing contributes to the development of...
Infusion of D1 Dopamine Receptor Agonist into Medial Frontal Cortex Disrupts Neural Correlates of Interval Timing
Medial frontal cortical (MFC) dopamine is essential for the organization of behavior in time. Our...
How to order:
Please contact the manufacturer, MicroProbes directly for further specifications and ordering. We would appreciate if you mention "Science Products" at any order or inquiry.